Jockey pump Controller

Controllers for high power electric Jockey Pumps 

SCF8M-J controllers, are complete user friendly and configurable instruments, useful for automatically operate up to 75 kW  Jockey pumps in any environment

SCF8M-J controllers  automatically start and stop Jockey pumps depending on the system’s demand; protect them by means of the connected and controller-generated alarms, visualize the most relevant values and informations, also manage the communication of the operator and both the contour elements and the remoted manned centre.

MAIN FEATURES: SCF8M-J

Medium size Jockey Fire Pumps controllers: EN 17451 / EN 12845 / NFPA 20

  • Nº STANDARDS & TECHNICAL RULES
    1 Standard EN 17451: 2024 / EN 12845: 2015
    2 Standard NFPA 20
    3 Standard UNE 23500: 2012 + 2021
    4 Standard UNI 10779: 2014
    5 Standard LPC TB210 / FOC
    6 Standard IEC 61439-1 Ed. 2011 Low-voltage switchgear and controlgear assemblies
    7 Tech. Rule CEPREVEN R.T.1-ROC: 2004
    8 Tech. Rule CEPREVEN R.T.2-ABA: 2006
  • Nº RANGE OF MODELS (according to type plate)
    1 Incoming line voltage 400 VAC / 230 VAC
    2 Mains frequency 50Hz / 60 Hz.
    3 Jockey pump size Up to 75 kW
    4 Motor starter type DOL / λ-Δ according to the motor power
  • Nº CONSTRUCTIVE FEATURES
    1 External enclosure IP65 Protected from total dust ingress (NEMA 4)
    2 Impact rating: IK10 (except for display)
    3 Fireproof grade: Fire extinguishes <30s
    4 Display Transflective: Visible under direct sunlight
    5 Wiring Halogen free
    6 Fireproof: RZ1 according to EN50200 (830ºC for 90min)
    7 Pump room temperature 20 ºF to 122ºF (-5ºC to 55ºC)
    8 Isolation rating between phases 500 VAC
    9 Isolation rating between phases and ground 2.500 VAC
    10 Isolation impedance between phases and ground 2 MΩ
    11 Earthing system TT system (neutral and earht connected separatelly )
    12 Electromagnetic environment CEM-1
  • Nº MEASURING INSTRUMENTS IN THE DISPLAY
    1 System 3 Voltmeter: voltage for every phase L1-L2-L3 (RMS)
    2 1 Mains frequency meter
    3 1 pump rotation/phase rotation
    4 1 Manometer pump discharge pressure ( pressure sensor required with 4-20 mA signal)
    5 Jockey pump 1 Ammeter: pump current (RMS)
    6 1 Active power in KW (RMS)
    7 1 Power factor (Cos φ)
    8 Controller 1 Voltmeter: Internal voltage
    9 Controller 1 Voltmeter: back-up battery voltaje
  • Nº PUMS & SYSTEM PROTECTION
    1 Voltage loss
    2 Normal power phase reversal
    3 Normal frequency loss
    4 Jockey pump protection trip
    5 Controller power loss
    6 Low water reservoir tank
    7 Low back-up battery voltage
    8 Main pump pressure switch open circuit
    9 Low power factor jockey pump
    10 Under-current Jockey pump
    11 Overload Jockey pump
    12 Pressure sensor fault
  • Nº COMMUNICATIONS & SIGNAL TRANSMISSION
    1 micro USB Port Boot loader for firmware upgrading
    2 SAF8M (control panel PLC ) configuration
    3 PC monitoring: Pump and installation general condition
    4 Pendrive data down-load: Events log / Pressures log
    5 ETHERNET (Optional) SAF8M (control panel PLC ) configuration
    6 PC monitoring: Pump and installation general condition
    7 RS485 port (Optional) SAF8M (control panel PLC ) configuration
    8 PC monitoring: Pump and installation general condition
    9 Voltage free contacts :
    up to 30 V DC / 0,3 A
    Voltage loss
    10 Pump non automatic mode
    11 Fail to start / not discharge pressure
    12 Grouped alarmas
    13 Pump on demand
    14 Pump running

     

  • Nº LANGUAGES / OTHER FEATURES
    1 ENGLISH / ESPAÑOL / ITALIANO / FRANÇAIS / PORTUGUES / DEUTSCH / NEDERLANDS
    2 System pressure meter: Value displayed on digital screen. Selection of demand and stop levels
    3 3 operatin modes: OFF/ MAN / AUTO
    4 Events log: Historical of 500 events in memory: Downloadable to pendrive
    5 Pressures register log: Historical of 16,000 records in memory: Downloadable to pendrive
    6 Jockey pump start count & hours and minutes
    7 Power elements: Contact breakers in AC-3 / Isolator switches in AC-23
SVE
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.