FIRE FIGHTING

SCF840-D-U

Cepreven

NEW
CERTIFIED / LISTED
EN12845 Diesel Fire pump Controller

SCF840-D-U controllers are high specifications, automatic and configurable instruments, useful for managing operations of any tipe diesel engine driven fire-fighting pumpsets, (Diesel Fire Pumps) of any power in any environment.

They govern the start and stop of the Diesel Fire Pumps and protect them by means of the action of the connected and controller-generated alarms, visualize the most relevant values and informations, also manage the communication with the operator and both the contour elements and the remote manned centre.

MAIN FEATURES

  • STANDARDS & TECHNICAL RULES
    1Standard EN 12845 Ed.2015
    2Standard UNE 23500 Ed.2021 & Ed. 2012
    3Standard UNI 10779 Ed. 2014
    4Standard IEC 61439-1 Ed. 2011 Low-voltage switchgear and controlgear assemblies
    5EMC: EN50130-4:2011 / IEC 62599-2:2010 / EN61000-6-3:2007
    6Electrical safety:EN61010-1:2011
  • RANGE OF PRODUCTS (according to the type plate)
    1Nominal supply voltage110Vac – 230 Vac (Consult other voltages)
    2Nominal frecuency50Hz / 60Hz.

    PANEL MODELS ACCORDING TO
    BATTERY CHARGERS
    SCF840-D-U 12030SCF840-D-U 12070SCF840-D-U 12100SCF840-D-U 24050SCF840-D-U 24100
    Nominal Voltage12 Vdc12 Vdc21Vdc24 Vdc24 Vdc
    Nominal Amps3 A7 A100 A5 A10 A
    DIN Power41,4 W96,6 W138,0 W138,0 W276,0 W
    Batteries capacity (C10)85,5 Ah200 Ah285 Ah142,5 Ah285 Ah
  • CONSTRUCTIVE FEATURES
    1CE marking: EMCEN50130-4:2011 / IEC 62599-2:2010 / EN61000-6-3:2007
    2CE marking; Electrical safetyEN61010-1:2011
    3EnclosureIngress protection rating according to EN 60529:2018: IP65
    4Protection against impacts degree according to EN60068-2-75:2014: IK10
    5Fireproof degree: The fire is extinguished in <30s with dripping
    6DisplayTFT full colour 3,5″ 480×272 px
    7CablingFree of halogens
    8Fire resistance: RZ1 according to EN50200 (Max: 830º / 90min)
    9Working temperaturesFrom -5ºC to 40ºC
    10Relative humidity (without condensation)Functional from 20 to 95%.
    11CoolingNatural convection
    12Maximum altitude2000m
    13Degree of contamination2
    14Overvoltage categoryII
    15EnvironmentCEM-I
    16Anti-vibration protectionEN60068-2-6:2008
  • MEASURING INSTRUMENTS IN THE DISPLAY
    1Batteries2 Voltmeter: Battery voltage
    22 Ammeter: Battery charging Amp
    41 Battery equalization timer
    5Engine1 Fuel tank level meter
    61 Oil pressure gauge (transducer not included)
    71 Engine wáter  thermometer (transducer not included)
    81 Engine oil thermometer (transducer not included)
    91 Engine speed meter (sensor not included)
    10Pump1 Pump demand pressure meter (transducer not included)
    111 Pump suction pressure meter (transducer not included)
    121 Flow meter ( manual introduction / 4⁄20mA sender not included)
    13System1 Voltmenter Vac supply voltaje
    141 Room temperature thermometer
  • PUMP & SYSTEM PROTECTION
    1MAINS FAILURE
    2OVER SPEED
    3LOW OIL PRESSURE
    4HIGH TEMPERATURE ENGINE
    5LOW TEMPERATURE ENGINE
    6LOW FUEL LEVEL
    7LOW BATTERY A VOLTAGE
    8LOW BATTERY B VOLTAGE
    9CHARGER A FAULT
    10CHARGER B FAULT
    11HEATER PROTECTION TRIPPED
    12CRANK ENGINE VOLTAGE FAIL
    13FAILED TO START
    14LOW DISCHARGE PRESSURE
    15LOW RESERVOIR TANK
    16LOW PRIMING TANK
    17SPEED SIGNAL FAULT
    18PRESSURE SWITCH SHORT-CIRCUIT
    19PRESSURE SWITCH OPEN-CIRCUIT
    20ELECTRIC MAINS FREQUENCY FAIL
    21FAULT COMMUNICATIONS I/O
    22FAULT COMMUNICATIONS WIFI
    23CRANKING LEVERS FAULT
    24LOW COOLANT TEMPERATURE
    25DC VOLTAGE FAIL
    26HIGH BATTERY A VOLTAGE
    27HIGH BATTERY B VOLTAGE
    28BATTERY A DEFECTIVE
    29BATTERY B DEFECTIVE
    30WATER PRESSURE SENSOR FAULT
    31SURGE ARRESTER FAULT
    32LOW FLOW COOLANT WATER
    33LOW AMBIENT TEMPERATURE
    34HIGH AMBIENT TEMPERATURE
    35ROOM TEMPERATURE TRANSDUCER FAILURE
    36TRIPPED HEATER PROTECTION
    37FAULT CRANKING MOTOR VOLTAGE
    38FAULT AUXILIARY ALTERNATOR
  • 1USB connector type ABFirmware updatin
    2WifiAccess to embedded website
    3Ethernet:  Modbus / TCP-IPPC monitoring: General status of the system and pumps
    4RS485  Modbus / RTUPC monitoring: General status of the system and pumps
    5Voltage free relays6 double relays 30 Vdc / 0,3 A
    61 double relay  250 Vac / 10 A
  • LANGUAGES / OTHER FEATURES
    1ESPAÑOL / ENGLISH / ITALIANO / FRANÇAIS / PORTUGUES
    2Monitored pressure switch lines: Short circuit / open circuit alarm
    3Monitored connection solenoid box. Cranking levers fault alarm
    4Pump demand  by pressure transducer analog reading of system pressure
    5Current date and time (RTC with independent battery)
    61200 last events log (starts, alarms, …)
    712,000 latest records of system pressure variation
    850 pressure / Flow pump test récords
    9Calibration of analog measurements: Pressure / Voltage / Temperature …
    10Digital and analog inputs and outputs checking of  on the display
    11Accumulate engine operations hours and minutes
    12Engine cooling circuit management
    13Engine heating resistence management