Controllers for Diesel Fire Pumps according to AS 2941 and AS 3000
SCF122-DI-AS2941 are designed to meet and exceed the requirements of the AS 2941 standard; They are high specification instruments that apply the most advanced technology. They offer unrivalled features such as communications, configurations, versatility and robustness.
SCF122-DI-AS2941 controllers govern the starting and stopping process of the Diesel Fire Pumps and protect them through the action of the alarms both connected and generated by the controller itself; they visualise the most relevant values and information, also manage the communication with the operator and with both the contour elements and the remote manned centre
MAIN FEATURES: SCF122-DI-AS2941
Diesel Fire Pump controller: AS 2941
Nº STANDARDS & TECHNICAL RULES 1 Standard AS 2914 Ed.2013 2 Standard AS/NZS 3000 Ed.2007 Nº RANGE OF PRODUCTS (according to the type plate) 1 Nominal supply voltage 230 Vac 2 Nominal frequency 50Hz / 60Hz. RANGE OF PANELS ACCORDING TO BATTERY CHARGERS SCF122-DI 12070 SCF122-DI 12100 SCF122-DI 24035 SCF122-DI 24050 Nominal Voltage 12 Vdc 12 Vdc 24 Vdc 24 Vdc Rated Amp 7 A 10 A 3,5 A 5 A DIN Power 96,6 W 138,0W 96,6 W 138,0 W Capacity of the batteries (C10) 200 Ah 285 Ah 100 Ah 142 Ah Nº CONSTRUCTIVE FEATURES 1 Enclosure Ingress protection rating: IP65 2 Protection against impacts degree: IK10 except PLC IGNIMATIC D122 3 Fireproof degree: The fire is extinguished in <30s with dripping 4 Display LCD 4 lines / 20 characters 5 Cabling Free of halogens 6 Fire resistance: RZ1 according to EN50200 (Max: 830º / 90min) 7 Working temperatures From -5ºC to 50ºC Nº MEASURING INSTRUMENTS IN THE DISPLAY 1 Batteries 2 Voltmeter: Battery voltage 2 2 Ammeter: Battery charging Amp 4 1 Battery equalization timer 5 Engine 1 Fuel tank level meter 6 1 Oil pressure gauge (sensor not included) 7 1 Engine temperature thermometer (sensor not included) 8 1 Engine speed meter (sensor not included) Nº PUMP & SYSTEM PROTECTION 1 System not in autamatic mode 2 Mains failure 3 Engine over-speed 4 Low oil pressure 5 High engine temperature 6 Low fuel level 7 Start battery low voltage 8 Monitor battery low voltage 9 Start battery charger fail 10 Monitor battery charger fail 11 Heater overload tripped 12 Start voltage fail 13 Fail to start 14 Pump pressure fail 17 Pick up fail 18 Coolant temperature fault Nº COMMUNICATIONS 1 RS485 port (Optional) IGNIMATIC D122 controller configuration 2 PC monitoring: Pump and installation general condition 3 Ethernet port (Optional) IGNIMATIC D122 controller configuration 4 PC monitoring: Pump and installation general condition 5 Voltage free contacts :
up to 30 V DC / 0,3 APower not available 6 Not in Automatic mode 7 Fail to start / not pump pressure 8 Grouped alarms (2 outputs) 9 Power fail 10 Pump running with pressure (2 Outputs) Nº LANGUAGES / OTHER FEATURES 1 ENGLISH/ ESPAÑOL / ITALIANO / FRANÇAIS / PORTUGUES 2 Engine heating management via temperature reading probe 3 Engine hours 4 Engine coolant circuit management 5 Buzzer: 80dB 6 Event historical: Last 47 events